Ei Electronics Ei413RF 868.499MHz Alarm Add-on für RF-Modul (Ei413)
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Externen Lager (16-23 Werktage)
Das Produkt befindet sich in einem externen Lager. Die Lieferfrist: ca. 16-23 Werktage. Mehr Info
Versandoptionen  - Wird im Checkout ausgewählt
Versand mit DHL - PaketShop
3,57
Versand mit DHL zur Adresse
11,90
Versand mit GLS - PaketShop
9,16
Versand mit GLS zur Adresse
11,90
EUR 107,10
ex. MwSt. 90,00
Gesamtbetrag inkl. Versand. 110,67
For convenience the Ei413 may be mounted inside the panel but care needs to be taken that the RF signal path is robust and reliable. We do not recommend that the Ei413 be placed inside a metal enclosure or in a posiOon where the RF signal could be seriously a?enuated. We recommend that close
a?enOon is paid to the posiOoning of the Ei413 during the installaOon.

It is possible to configure the wiring of the Fire and Fault relays so that the fire panel may indicate both Fire and Fault condiOons. Consult the panel manufacturer’s end of line (EOL) terminaOon details when choosing this configuraOon.

The Ei413 Panel Module provides an interface between an Ei Electronics RadioLINK system and a security or fire panel system. A RadioLINK system consists of Ei Electronics Smoke, Heat, CO Alarms
along with accessory devices that are linked using a proprietary RF protocol. The Ei413 must be coded to the other RadioLINK devices in the system. The Ei413 requires an 11-30VDC supply which is normally taken from the panel.
The Ei413 decodes “Fire”, “CO” and “Fault” signals from the RadioLINK devices and acOvates the relevant onboard relays. The relays are wired to input terminals on the panel. The NO voltage free contacts input and/or the DC voltage input, when acOvated, will result in the Ei413 transmitng a wireless Fire Alarm signal that will sound all the alarms in the RadioLINK system. These inputs are acOvated by a Fire Alarm signal or a Test Alarm signal from the panel.
The Ei413 uses RadioLINK mulO-repeater, mulO-path technology to deliver very robust and reliable RF signal coverage.